Abstract

The aim of this study was to compare the incidence of root canal dentinal micro-cracks after canal instrumentation using reciprocating files (WaveOne Gold® and Twisted Adaptive®) and continuous rotation files (Edge Evolve® and EndoSequence®) in an ex-vivo benchtop study. This project used a novel methodology of finding dentinal defects using the “K-cube”, which allows evaluators to visualize sectioned root surfaces before instrumentation and after instrumentation. Mesial roots from 40 human mandibular first molars were divided into 4 groups of 10 for each file type. Root section pictures were taken with a Zeiss Discovery V20 stereomicroscope before and after canal instrumentation. Each of the pre-instrumentation and post-instrumentation images were evaluated for dentinal defects by four calibrated endodontists utilizing REDCap survey. Using a chi-square analysis, there was no statistically significant difference between dentinal defects created by continuous and reciprocating rotation (p=0.1924) and no difference between the four file types (p=0.2317).